AEMC 1 Channel Current Simple Logger II
>> 3 User Selectable Storage Modes
>> 240,000 Samples Stored in Non-Volatile Memory
>> 5 LED Indicators Quickly and Clearly Display Logger Status
>> Records up to 64 Samples/Cycle
>> Includes DataView Software for Real-Time Waveform Display, Analysis and Report Generation
>> Requires a Current Probe Compatible with Voltage Output and BNC Connection
Required with Current Simple Logger®
>> Current Probes w/ BNC Connector
Current Simple Logger® Specifications
| Current Probe Output | 0 to 1 Volt (Probe Dependant) |
| Number of Channels | 1 Channel |
| Input Connection | BNC Connector for Each Channel |
| Resolution | 0.1 mV |
| Accuracy (50/60 Hz) |
0 to 10mV: Unspecified 10 to 50mV: ±(0.5% of Reading + 1mV) 50 to 1000mV: ±(0.5% of Reading + 0.5mV) |
| Sample Rate | 64 Samples/Cycle |
| Storage Modes | Start/Stop, FIFO and Extended Recording Mode (XRM™) |
| Storage Rate | Programmable from 125ms to 1 Day |
| Recording Length | 15 Minutes to 8 Weeks Programmable Using DataView Software |
| Data Storage Capacity | 240,000 Readings/Measurements (Stored in Non-Volatile Memory, Retained If Battery is Low or Removed) |
| Communication | USB 2.0 Optically Isolated |
| Power Source | (2) 1.5 Volt AA-cell Alkaline Batteries |
| Battery Life | 100 Hours to > 45 Days (Dependent on Sample Rate and Recording Length) |
| Max Conductor Size | Current Probe Dependant |
| Case | UL94-V0 |
| Vibration | IEC 68-2-6 (1.5mm, 10 to 55Hz) |
| Shock | IEC 68-2-27 (30G) |
| Drop | IEC 68-2-27 (1m) |
| Software | DataView Software (Included) |
| OS Compatibility | Windows XP, Vista and 7 (32-bit and 64-bit) |
| Dimensions | 5.38" x 2.75" x 1.28" (136mm x 70mm x 32mm) |
| Weight | 6.4 oz (181 grams) |
![]() |
TRMS 1 Channel Current Simple Logger Includes:
>> DataView Software >> (2) AA Alkaline Batteries |
Part #: L101 | ||||||
| Current Probes 1 - Required | ||||||||
![]() |
AC Current Probe with BNC Connector >> Measurement Range: 0.1 to 24A, 0.5 to 40A
>> Nominal Range: 20Amp, 200 Amp >> Output: 10 mV/A, 100 mV/A >> Connection: BNC |
Part #: MN261 | ||||||
![]() |
AEMC AC Current Probe >> Measurement Range: 0.1 to 2000 Apk
>> Nominal Range: 20 Apk, 200 Apk, 2000 Apk >> Output: 10mA to 20A, 0.1A to 200A, 1A to 2000A >> Connection: BNC |
Part #: SR661 | ||||||
![]() |
AC Current Probe with BNC Connector >> Measurement Range: 90A, 900A, 9000A
>> Nominal Range: 30Amp, 300 Amp, 3000 Amp >> Output: 10 mV/Aac, 1 mV/Aac, 0.1 mV/Aac >> Connection: BNC |
Part #: JM861 | ||||||
| Optional Accessories | ||||||||
![]() |
AA Lithium Batteries >> 4 Pack
|
|
||||||
Current Simple Logger® Applications
- Load and Split Phase Load Profiling
- Fault Current Detection
- Intermittent Problem Detection
- Demand Recording
- Neutral Current Monitoring
- Harmonic Current Recording Using DataView Software
- Metering CT Resizing
- Neutral and Ground Current Monitoring
- Machine Load Monitoring