  • 16 (Single Ended) or 8 (Differential) High Speed Analog Inputs Sampling up to 500 k/s
  • Software Selectable Input Ranges of ±10 Volts, ±5 Volts, ±2 Volts or ±1 Volts per Channel
  • Features 8 Bi-Directional and Individually Configurable Digital I/O, (2) Counter Input Channels and 1 Timer Output Channels
  • Powered by 5 Volt USB Cable Attached to Your Computer, Eliminating External Power Supply
  • Includes Measurement Computing DAQ Software Suite

Thermocouples

Thermocouples for use with thermocouple data loggers.

 

 

Type K Pipe Clamp Temperature Probe

  1. Spring-Loaded Jaw for Secure Grip on Pipes (0.25" to 1.5" dia.)
  2. Temperature Range: -4°F to 200°F (-20°C to 93°C)
  3. Accuracy: ±3.6°F (1.8°C)
  4. Includes 36" (0.9m) Cable and Type K Connector.

 

 

USB Serial Adapter

The USB Serial adapter can be used to connect many data loggers that require a serial port connection to an available USB ports on a PC.

 

 

 

Protective Cases and Shields

Multi-Purpose Shelter

The Multi-Purpose Shelter gives you a number of different outdoor storage options for dataloggers.

Includes 16' (5 m) ground wire. Dimensions: 3.75" x 9.5" x 12.5" (95 x 240 x 320 mm).

 

 

Radiation Shield

The most effective passive shelter available. Protects your Temperature or Temperature/Humidity Sensor from solar radiation and other sources of radiated and reflected heat. Multi-plate construction for maximum airflow. Asssembly required. May be used with Sensor Mounting Arm or mounted on metal pipe or wood surface.

 

 

Software and Cables for Data Loggers

Many of the data loggers found on MicroDAQ.com need a software and cable kit for operation. Refer to the page of the data logger you are interested in for information on the required software kit.

Solar Power Kit

The Davis solar panel is rated at 10 Watts. It provides about 600 mA of current in bright sunshine (1000 W/m2). Includes solar panel, regulator circuit, rechargeable battery, and 20' (6 m) cable.

  1. You may change quantities from within your cart.
  2. If you do not wish to order online call us toll free at 877-275-9606 between the hours of 9-5 Eastern Standard time.
  • 0.2% Accuracy Class Revenue and Demand Submeter0.2% Accuracy Class Revenue and Demand Submeter RS485 (Standard) or Optional WiFi/Ethernet Communications 3 Line LED Display Utility Grade Test Pulse for Revenue Metering and Accuracy Verification/Certification 2 MB of Storage for Data Logging Historical Trends, Limit Alarms and Sequence of Events Includes CommunicatorEXT 3.0 Windows Software
  • RS485 (Standard) or Optional WiFi/Ethernet Communications
  • 3 Line LED Display
  • Utility Grade Test Pulse for Revenue Metering and Accuracy Verification/Certification
  • 2 MB of Storage for Data Logging Historical Trends, Limit Alarms and Sequence of Events
  • Includes CommunicatorEXT 3.0 Windows Software
  • 3 channel logger with 8-bit resolution recording up to 21,800 x-, y-, and z-axis Acceleration Readings or Internal Logger Events
  • Measures G Forces,Tilt, Orientation, Activity and Motion
  • Long-Lasting User Replaceable Battery
  • Compatible with HOBO Shuttle and U-Shuttle
  • Available as a Kit with HOBOware Lite Software and Optic USB Interface Cable
  • Measures Current, Voltage, Resistance, High Voltage, Pulse and Digital Event/State Inputs
  • Built-in RS-232, USB and Wireless or Ethernet Ports
  • 16 True Differential or 32 Single Ended Universal Analog Input Channels
  • Standard Sampling Rate up to 10Hz with 20Hz and 100Hz Sampling Rates Available
  • 0.05% Measurement Accuracy
  • Features Alarms, LCD Display and Removable SD Card
  • Stores up to 1.8 Million Readings
  • Includes USB Cable, Batteries, Current Shunt Resistors, Software and User Manual
  • Measure temperature, relative humidity (RH), light intensity, CO2, AC current, 4-20mA, 0-2.5V DC
  • High-accuracy temp and relative humidity
  • 12-bit resolution
  • 43K readings
  • Direct USB interface
  • measure and Record Using J, K or T Type Thermocouple Probe
  • LCD Display and Alarms
  • ±1.0°C Accuracy
  • USB Interface for Easy Set-up and Download of Data
  • Includes Software, battery and K-Type Probe
  • Displays Current Temperature and Humidity Readings on LCD Display
  • 0°C to 50°C (Temperature) and 5% to 95% (Humidity) Measurement Range Using External Sensor
  • Accepts Type K or J Thermocouples for Additional Temperature Recording
  • Battery Powered with Optional AC/DC Power Adapter Available
  • Optional SD Card (Sold Separately) Available to Log all Recorded Data
  • Records events and temperaturesolution team
  • Can be used to records tips from third-party tipping-bucket rain gauges
  • NEMA 6 rated weatherproof housing
  • The Pendant Event/Temp Data Logger is a rugged, weatherproof event logger with a 10-bit temperature sensor. It is ideal for use with tipping-bucket rain gauges, and can record tens of thousands of measurements and events. The logger features a 2-wire interface cable for measuring mechanical and electrical contact closures, user-replaceable battery and a 1.5 meter drop specification.
  • 8 channel data logger with graphical display
  • 16 bit resolution
  • Selectable type for each input: 0-24mA, 0-50mV, 0-10V, NTC, PT-100, Thermocouple, Pulse and frequency
  • Includes Carrying Case, User Manual on CD, Software, USB cable and Certificate of Calibration